HP line modules
The decision to offer highly targeted products and simple to use, has led us to realize the 68 models in this article.
HP10 Thermometer with recorder
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
---
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP11 Single-level thermostat
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP13 Double-level alarm
|
Handbook
|
Inputs: |
|
1 temperature probe SX (with min & max value recording) |
Outputs: |
|
1 fuse protected (T 4A) exchange contact |
Range: |
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) |
Including: |
|
|
Optionals: |
|
|
|
|
|
HP14 Double-level hygrostat
|
|
Inputs: |
|
1 humidity probe (with min & max value recording) |
Outputs: |
|
2 fuse protected (T 4A) exchange contact |
Range: |
|
(0.0 ...99.9% Rh) |
Including: |
|
|
Optionals: |
|
|
|
|
|
HP15 Double single-level thermostat
|
Handbook
|
Inputs: |
|
2 temperature probe SX (with min & max value recording on 1st) |
Outputs: |
|
2 fuse protected (T 4A) exchange contact |
Range: |
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) |
Including: |
|
|
Optionals: |
|
|
|
|
|
HP16 Double double-level alarm
|
Handbook
|
Inputs: |
|
2 temperature probe SX |
Outputs: |
|
2 fuse protected (T 4A) exchange contact |
Range: |
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) |
Including: |
|
|
Optionals: |
|
|
|
|
|
HP17 Thermostat with alarm
|
Handbook
|
Inputs: |
|
1 temperature probe SX (min & max value recording) |
Outputs: |
|
2 fuse protected (T 4A) exchange contact |
Range: |
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) |
Including: |
|
|
Optionals: |
|
|
|
|
|
HP18 Freezer store controller
|
Handbook
|
Inputs: |
|
2 temperature probe SX (1 with min & max value recording) 1 external input (defrost) |
Outputs: |
|
2 normally open contact |
Range: |
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) |
Including: |
|
|
Optionals: |
|
|
|
|
|
HP19 Multi-timer
|
Handbook
|
Inputs: |
|
--- |
Outputs |
|
1 fuse protected (T 4A) exchange contact |
Range: |
|
0.1 Sec < > 520 Min |
Including: |
|
---
|
Optionals: |
|
|
|
|
|
----------------------------------------------------------------
HP20 Radiant controller 3 level + spark ignit.
|
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP21 Single level thermostat
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP22 Double level thermostat
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP23 Floating proportional
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP24 Double single-level thermostat
|
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP25 Double double-level thermostat
|
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP26 Double floating proportional
|
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP27 Single-level hygrostat
|
|
Inputs:
|
|
1 humidity probe (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(0.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP28 Radiant proportional controller
|
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
3 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP29 Ventilation Surveyor
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
----------------------------------------------------------------
HP30 Double level + neutral band controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP31 Luminosity controller
|
|
Inputs:
|
|
1 luminosity probe LX (with min & max value recording)
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(0.0 ...99.9%)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP32 Proportional feedback
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording) 1 response potentiometer
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP33 Wind surveyor
|
|
Inputs:
|
|
2 wind meter WX (1 with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
0.0 < > 99.9 (Km/h - m/sec - Knots)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP34 Temperature-luminosity controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording) 1 luminosity probe LX
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (0.0 ...99.9%)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP35 Psychrometer hygrostat controller
|
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(0.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP36 On-Off ventilation controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP37 4 steps ventilation
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP38 4 steps ventilation
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP39 Freezer store controller
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
----------------------------------------------------------------
HP40 Green-house controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording) 1 humidity probe electronic / psychrometric
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (10.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP41 Green-house controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording) 1 humidity probe electronic
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (10.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP42 Green-house controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP43 Quad-zone alarm
|
|
Inputs:
|
|
4 temperature probes SX
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP44 Multiprogrammable
|
|
Inputs:
|
|
4 temperature probes SX
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP45 Warm-air generator controller
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
2 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
3 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP46 Egg-discloser
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording) 1 humidity probe electronic 4-20mA / SXPS
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (10.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP47 Thermal chamber controller
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
3 temperature probes SX 1 electronic humidity probe
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (10.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP48 Freezer store controller
|
|
Inputs:
|
|
3 temperature probes SX 1 external input (man. defrost)
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (10.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP49 Proportional Feedback
|
|
Inputs:
|
|
1 position encoding step 1 potentiometer response
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
---
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
----------------------------------------------------------------
HP50 Tobacco thermal chamber
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
3 temperature probes SX
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP51 0-10V flexible read-out
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
1 0-10V (min & max value recording)
|
Outputs:
|
|
---
|
Range:
|
|
0% < > 100%
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP52 Differential thermostat
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
2 temperature probes SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP53 4 steps ventilation
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP54 4 steps ventilation + thermoreg.
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
4 normally open contacts 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP55 Oven programmable controller
|
|
Inputs:
|
|
1x J,K,N,R,S,T,PT100,PT1000,SX POLA
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
-200 °C < > +1500 °C
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP56 PID thermocouple controller
|
|
Inputs:
|
|
1x J,K,N,R,S,T,PT100,PT1000,SX POLA
|
Outputs:
|
|
1 exchange contact 1 solid state relay
|
Range:
|
|
-200 °C < > +1500 °C
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP57 Thermo-Hygrostat Controller
|
|
Inputs:
|
|
1 temperature probe SX 1 temperature probe SXPS
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (0.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP58 0-10V Proportional
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
1 exchange contact 1 output 0-10V Dc
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP59/W Air Pressure Control
|
|
Inputs:
|
|
2 air inputs (environment + external)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts 1 (0.5 V <> 4.5 V)
|
Range:
|
|
0.0 mBar < > 3.0 mBar (0.0/30.0 mmH2O)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
----------------------------------------------------------------
HP60 Weight controller
|
|
Inputs:
|
|
Load cells
|
Outputs:
|
|
1 exchange contact
|
Range:
|
|
Multirange
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
Weight controller with entry for load cells (digital amplifier at 65.000 points, integrated on board)
HP60 realizes the following functions:
- possibility to work with increase or decrease of weight; - "flight" weight setting; - setting flexibility of the decimal point of weight displayed; - tare key; - start/stop key of load/unload weight;, - setting key of load/unload weight.
The digital amplifier at 65.500 points with precision and a stability of 1 point on 65.500 and a termic drift of less than one point on 65.500 integrated on board of HP60 permits an exact control of the weighing, in order to connect every kind of load cells with an automatic procedure of cells calibration (no trimmers to adjust): pratically the precision of weighing system is the one that is declared of load cells.
|
|
|
|
|
HP61 Silo weight controller
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
Load cells
2 external contacts
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
Multirange
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
Silo weight controller with entry for load cells* (digital amplifier at 65.500 points, integrated on board), litres counter for water calculation*, daily start clock*, sensor maximum charge of distribution's line*.
*Item that we don't supply.
HP61 doses the programmed quantity of feed to distribute with resolution to Kg and in the meantime it realizes the following functions:
- it verifies that during the distribution the feed reduces in the silo (stopping the distribution and signalling the alarm if a non-decrease of the weight occurs due to effect "bridge" of the feed in the silo); - it verifies that the distribution of the programmed quantity of feed happens in a prefixed time (stopping the distribution and signalling the alarm if an overcoming of maximum time occurs); - it verifies the signal of the sensor of maximum charge of distribution line of the feed (stopping the distribution when the sensor intervenes and starting it again with a certain time of delay when the sensor permits it); - it records the Kg of feed that have been consumed from the first day of the cycle; - it records the litres of water that have been consumed from the first day of the cycle; - it verifies in each moment the feed that has been loaded.
The digital amplifier at 65.500 points with precision and a stability of 1 point on 65.500 and a termic drift of less than one point on 65.500 integrated on board of HP61 permits an exact control of the weighing, in order to connect every kind of load cells with an automatic procedure of cells calibration (no trimmers to adjust): pratically the precision of weighing system is the one that is declared of load cells.
|
|
|
|
|
HP62 Hopper weight controller
|
Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order ! |
|
Inputs:
|
|
Load cells
3 external contacts
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
Multirange
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
|
- Hopper weight controller with entry for load cells*
- Digital amplifier at 65.500 points, integrated on board
- Litres counter for water calculation*
- aily start clock*
- Sensor maximum charge of distribution's line*
*Item that we don't supply.
HP62 doses the programmed quantity of feed to distribute with resolution to Hectogram and in the meantime it realizes the following functions:
- it verifies that during the distribution the feed increases in the hopper (stopping the distribution and signalling the alarm if a non-decrease of the weight occurs due to effect "bridge" of the feed in the silo); - it verifies that the distribution of the programmed quantity of feed happens in a prefixed time (stopping the distribution and signalling the alarm if an overcoming of maximum time occurs); - it verifies that the quantity of feed that is present in the silo doesn't fall under the prefixed quantity of "minimum supply" (signalling with the alarm the overcoming of this condition); - it verifies the signal of the sensor of maximum charge of distribution line of the feed (stopping the distribution when the sensor intervenes and starting it again with a certain time of delay when the sensor permits it); - it records the Kg of feed that have been consumed from the first day of the cycle; - it records the litres of water that have been consumed from the first day of the cycle; - it verifies in each moment the feed that is present.
The digital amplifier at 65.500 points with precision and a stability of 1 point on 65.500 and a termic drift of less than one point on 65.500 integrated on board of HP62 permits an exact control of the weighing, in order to connect every kind of load cells with an automatic procedure of cells calibration (no trimmers to adjust): pratically the precision of weighing system is the one that is declared of load cells.
|
|
HP63 Silos weight repeater
|
|
Inputs:
|
|
Bus 485 |
Outputs:
|
|
--- |
Range:
|
|
Kg / Qli
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP63/W is a repeater of the silos weight so the value can be easily read near the silos. It has been designed for outdoor installation and 1 units can be connected for each silos. It can be connected to the 485 weight bus, available on the TLC2 loadcells amplifier located near the silos (only for connection with Gt Farm, Xfarm and Qfarm). |
|
|
|
|
HP64 Hopper time/weight controller
|
|
Inputs:
|
|
4 external contacts
|
Outputs:
|
|
3 normally open contacts
|
Range:
|
|
---
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
Hopper time/weight controller without load cells, litres counter for water calculation*, daily start clock*, sensor maximum charge of distribution's line*.
*Item that we don't supply.
HP64 doses the programmed quantity (time/weight) of feed to distribute and in the meantime it realizes the following functions:
- it verifies that the distribution of the programmed quantity of feed happens in a prefixed time (stopping the distribution and signalling the alarm if an overcoming of maximum time occurs); - it verifies the signal of the sensor of maximum charge of distribution line of the feed (stopping the distribution when the sensor intervenes and starting it again with a certain time of delay when the sensor permits it); - it records the Kg of feed that have been consumed from the first day of the cycle; - it records the litres of water that have been consumed from the first day of the cycle;
|
|
|
|
|
HP66 Ventilation & Cooling
|
|
Inputs:
|
|
1 temperature probe SX 1 humidity probe electronic 4-20mA / SXPS
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F) (10.0 ...99.9% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP68 Lights sequence
|
|
Inputs:
|
|
1 0-10v
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
---
|
Including:
|
|
|
Optionals:
|
|
|
|
HP68 allows you to operate ceiling dual lamp with a lamp in regulation 0-10V (incandescent) and a lamp On-Off (neon). In the initial phase (Dawn) it is adjusted increasing the brightness of incandescent lamps (via its 0-10V output of Gt Farm); reached the maximum% brightness of the lamps (incandescent) the neon lights are lit up, then the incandescent lamps are turned off (after a programmable delay time). It continues with the neon lights on (and incandescent lamps off) until the initial phase of the sunset, when incandescent lights are 100% turned on, after this the neon lamps are turned off (after a delay time programmable). The sunset is terminated with the arrival to the % of brightness programmed on Gt Farm. In the case of a single ceiling lamp (with neon lamp in regulation 0-10V) you can control a line counter to switch off the lights. |
|
HP69 0-10V light control
|
|
Inputs:
|
|
1 external contact
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
---
|
Including:
|
|
|
Optionals:
|
|
|
|
HP69 allows you to operate an output in 0-10V regulation with an ascending ramp and one descending: the start signal (start signal closed) powers up the ascending ramp that maintains the output value until the start of the descent ramp (start signaI open). Furthermore below the set minimum % set of brightness the relay turns completely the lamps off. |
|
----------------------------------------------------------------
HP70 Ventilation proportional 0-10V
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts 1 output 0-10V
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP71 0-5v Steps translator
|
|
Inputs:
|
|
1 0-5v
|
Outputs:
|
|
4 normally open contacts 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
---
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP72 Sprinkler controller
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
2 fuse protected (T 4A) exchange contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP73 Proportional feedback
|
|
Inputs:
|
|
1 0-10V 1 Feedback potentiometer
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
---
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP74 Ventilation controller 0-10V + 4 steps On-Off
|
|
Inputs:
|
|
1 temperature probe SX (with min & max value recording)
|
Outputs:
|
|
1 output 0-10v 1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
HP75 CO2 Surveyor
|
|
Inputs:
|
|
1 carbon dioxide probe (CO2)
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(0...10.000ppm)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
|
HP75 keeps control on the CO2 ambient value and records the min/max daily value up to 99 days cycle (and hourly values of the last 60 hours). Afterwards the oldest daily and hourly records are automatically deleted by the new ones. A CO2 alarm value can be set so an output contact is activated. |
|
|
|
|
HP76 Humidity Surveyor (electronic probe)
|
|
Inputs:
|
|
1 humidity probe electronic
|
Outputs:
|
|
1 fuse protected (T 4A) exchange contact
|
Range:
|
|
(0...100% Rh)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|
|
HP76 keeps control on the humidity ambient value and records the min/max daily value up to 99 days cycle (and hourly values of the last 60 hours). Afterwards the oldest daily and hourly records are automatically deleted by the new ones. A humidity alarm value can be set so an output contact is activated. |
|
|
|
|
HP77 Humidity Surveyor (psychrometer probe)
|
|
Inputs: |
|
1 temperature probe SX (dry) 1 temperature probe SX1 (wet) |
Outputs: |
|
1 fuse protected (T 4A) exchange contact |
Range: |
|
(0.0...100% Rh) |
Including: |
|
|
Optionals: |
|
|
|
|
|
|
HP77 keeps control on the humidity ambient value and records the min/max daily value up to 99 days cycle (and hourly values of the last 60 hours). Afterwards the oldest daily and hourly records are automatically deleted by the new ones. A humidity alarm value can be set so an output contact is activated. |
|
|
|
|
HP79 Single-level hygrostat (electronic probe)
|
|
Inputs: |
|
1 humidity probe electronic |
Outputs: |
|
1 fuse protected (T 4A) exchange contact |
Range: |
|
(0...100% Rh) |
Including: |
|
|
Optionals: |
|
|
|
|
|
|
HP96 Amperometric controller
|
|
Inputs:
|
|
3 TA
1 temperature probe SX
|
Outputs:
|
|
4 normally open contacts
|
Range:
|
|
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
|
Including:
|
|
|
Optionals:
|
|
|
|
|
|