pan HP collageThe decision to offer highly targeted products and simple to use, has led us to realize the 68 models in this article.

 

 

 

 
HP10 <> HP19
HP10 Thermometer with recorder   HP15 Double single-level thermostat
HP11 Single-level thermostat   HP16 Double double-level alarm
HP12 Double-level thermostat   HP17 Thermostat with alarm
HP13 Double-level alarm   HP18 Freezer store controller
HP14 Double-level hygrostat   HP19 Multi-timer
 
 
 
  

 

HP10 Thermometer with recorder

pan HP10
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
 ---
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP11 Single-level thermostat

pan HP11
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP12 Double-level thermostat

pan HP12
 
icona pdf 50px
Handbook
Inputs:   1 temperature probe SX (with min & max value recording)
 Outputs:   2 fuse protected (T 4A) exchange contact
 Range:   (-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:   sx
Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

 

HP13 Double-level alarm

pan HP13

icona pdf 50px
Handbook

Inputs:   1 temperature probe SX (with min & max value recording)
 Outputs:   1 fuse protected (T 4A) exchange contact
 Range:   (-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:   sx
Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

 

HP14 Double-level hygrostat

pan HP14

Inputs:   1 humidity probe (with min & max value recording)
 Outputs:   2 fuse protected (T 4A) exchange contact
 Range:   (0.0 ...99.9% Rh)
 Including:    
Optionals:   ghp  ct  ttl plug foto - Copia     rhr ha20
     freccia su

 

HP15 Double single-level thermostat

pan HP15

icona pdf 50px
Handbook

Inputs:   2 temperature probe SX (with min & max value recording on 1st)
 Outputs:   2 fuse protected (T 4A) exchange contact
 Range:   (-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:    sxsx
Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

 

HP16 Double double-level alarm

pan HP16

icona pdf 50px
Handbook

Inputs:   2 temperature probe SX
 Outputs:   2 fuse protected (T 4A) exchange contact
 Range:   (-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:    sxsx
Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

 

HP17 Thermostat with alarm

pan HP17  

icona pdf 50px
Handbook

Inputs:   1 temperature probe SX (min & max value recording)
 Outputs:   2 fuse protected (T 4A) exchange contact
 Range:   (-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:    sx
Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

 

HP18 Freezer store controller

pan HP18  

icona pdf 50px
Handbook

Inputs:   2 temperature probe SX (1 with min & max value recording)
1 external input (defrost)
 Outputs:   2 normally open contact
 Range:   (-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:    sx1sx1
Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

 

HP19 Multi-timer

pan HP19

icona pdf 50px
Handbook

Inputs:    ---
Outputs   1 fuse protected (T 4A) exchange contact
 Range:   0.1 Sec < > 520 Min
 Including:  

 ---

Optionals:   ghp  ct  ttl plug foto - Copia
     freccia su

  

 ----------------------------------------------------------------

 

HP20 Radiant controller 3 level + spark ignit.

pan HP20
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsx
Optionals:
 
ghp  ct  ttl plug foto - Copia 
     freccia su

 

HP21 Single level thermostat

pan HP21
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP22 Double level thermostat

pan HP22
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP23 Floating proportional

pan HP23
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia      
     freccia su



 

HP24 Double single-level thermostat

pan HP24
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP25 Double double-level thermostat

pan HP25
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP26 Double floating proportional

pan HP26
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP27 Single-level hygrostat

pan HP27
 
Inputs:
 
1 humidity probe (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(0.0 ...99.9% Rh)
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia    rhr ha20 
     freccia su

 

HP28 Radiant proportional controller

pan HP28
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
3 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP29 Ventilation Surveyor

pan HP29
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia  
     freccia su

  

----------------------------------------------------------------

 
   

HP30 Double level + neutral band controller

pan HP30
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia 
     freccia su

 

HP31 Luminosity controller

pan HP31
 
Inputs:
 
1 luminosity probe LX (with min & max value recording)
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(0.0 ...99.9%)
 Including:
 
lx
Optionals:
 
ghp  ct  ttl plug foto - Copia   
     freccia su

 

HP32 Proportional feedback

pan HP32
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
1 response potentiometer
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia  pt
     freccia su

 

HP33 Wind surveyor

pan HP33
 
Inputs:
 
2 wind meter WX (1 with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
0.0 < > 99.9 (Km/h - m/sec - Knots)
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia  wx
     freccia su

 

HP34 Temperature-luminosity controller

pan HP34
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
1 luminosity probe LX
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(0.0 ...99.9%)
 Including:
 
sxlx
Optionals:
 
ghp  ct  ttl plug foto - Copia 
     freccia su

 

HP35 Psychrometer hygrostat controller

pan HP35
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(0.0 ...99.9% Rh)
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia wt1
     freccia su

 

HP36 On-Off ventilation controller

pan HP36
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP37 4 steps ventilation

pan HP37
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP38 4 steps ventilation

pan HP38
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP39 Freezer store controller

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP39
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx1sx1ttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

  

----------------------------------------------------------------

 
   

HP40 Green-house controller

pan HP40
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
1 humidity probe electronic / psychrometric
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(10.0 ...99.9% Rh)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct  hpalwt1 rhr ha20 
     freccia su

 

HP41 Green-house controller

pan HP41
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
1 humidity probe electronic
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(10.0 ...99.9% Rh)
 Including:
 
sx
Optionals:
 
ghp  ct     rhr ha20 
     freccia su

 

HP42 Green-house controller

pan HP42
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal 
     freccia su

 

HP43 Quad-zone alarm

pan HP43
 
Inputs:
 
4 temperature probes SX
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsxsxsx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP44 Multiprogrammable

pan HP44
 
Inputs:
 
4 temperature probes SX
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsxsxsxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP45 Warm-air generator controller

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP45
 
Inputs:
 
2 temperature probe SX (with min & max value recording)
 Outputs:
 
3 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP46 Egg-discloser

pan HP46
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
1 humidity probe electronic 4-20mA / SXPS
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(10.0 ...99.9% Rh)
 Including:
 
ttl plug foto - Copia
Optionals:
 
ghp  ct  hpal sxwt1 rhr ha20 
     freccia su

 

HP47 Thermal chamber controller

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP47
 
Inputs:
 
3 temperature probes SX
1 electronic humidity probe
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(10.0 ...99.9% Rh)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal    rhr ha20 
     freccia su

 

HP48 Freezer store controller

pan HP48
 
Inputs:
 
3 temperature probes SX
1 external input (man. defrost)
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(10.0 ...99.9% Rh)
 Including:
 
sx1sx1ttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP49 Proportional Feedback

pan HP49
 
Inputs:
 
1 position encoding step
1 potentiometer response
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
---
 Including:
   
Optionals:
 
ghp  ct
     freccia su

 

 ----------------------------------------------------------------

  

HP50 Tobacco thermal chamber

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP50
 
Inputs:
 
3 temperature probes SX
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx1sx1 sxa1
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP51 0-10V flexible read-out

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP51
 
Inputs:
 
1 0-10V (min & max value recording)
 Outputs:
 
---
 Range:
 
0% < > 100%
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP52 Differential thermostat

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP52
 
Inputs:
 
2 temperature probes SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxsx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP53 4 steps ventilation

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP53
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP54 4 steps ventilation + thermoreg.

pan HP54
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
4 normally open contacts
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct  hpal
     freccia su

 

HP55 Oven programmable controller

pan HP55
 
Inputs:
 
1x   J,K,N,R,S,T,PT100,PT1000,SX POLA
 Outputs:
 
4 normally open contacts
 Range:
 
-200 °C < > +1500 °C
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP56 PID thermocouple controller

pan HP56
 
Inputs:
 
1x   J,K,N,R,S,T,PT100,PT1000,SX POLA
 Outputs:
 
1 exchange contact
1 solid state relay
 Range:
 
-200 °C < > +1500 °C
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP57 Thermo-Hygrostat Controller

pan HP57
 
Inputs:
 
1 temperature probe SX
1 temperature probe SXPS
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(0.0 ...99.9% Rh)
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copiawt1rhr ha20
 
     freccia su

 

HP58 0-10V Proportional

pan HP58
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
1 exchange contact
1 output 0-10V Dc
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)

 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP59/W Air Pressure Control

pan HP59W
 
Inputs:
 
2 air inputs (environment + external)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
1 (0.5 V <> 4.5 V)
 Range:
 
0.0 mBar < > 3.0 mBar (0.0/30.0 mmH2O)
 Including:
 
pa  pa tubo depressimetro
Optionals:
   
     freccia su

  

----------------------------------------------------------------

 

 

HP60 Weight controller

pan HP60
 
 
 
 
 
Inputs:
 
Load cells
 Outputs:
 
1 exchange contact
 Range:
 
Multirange
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia  cn5-u10
     

Weight controller with entry for load cells (digital amplifier at 65.000 points, integrated on board)

HP60 realizes the following functions:

- possibility to work with increase or decrease of weight;
- "flight" weight setting;
- setting flexibility of the decimal point of weight displayed;
- tare key;
- start/stop key of load/unload weight;,
- setting key of load/unload weight.

The digital amplifier at 65.500 points with precision and a stability of 1 point on 65.500 and a termic drift of less than one point on 65.500 integrated on board of HP60 permits an exact control of the weighing, in order to connect every kind of load cells with an automatic procedure of cells calibration (no trimmers to adjust): pratically the precision of weighing system is the one that is declared of load cells.

      freccia su

 

HP61 Silo weight controller

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP61
 
 
 
 
 
Inputs:
 
Load cells
2 external contacts
 Outputs:
 
4 normally open contacts
 Range:
 
Multirange
 Including:
   ttl plug foto - Copia
Optionals:
 
ghp  ct    cn5-u10
     

Silo weight controller with entry for load cells* (digital amplifier at 65.500 points, integrated on board), litres counter for water calculation*, daily start clock*, sensor maximum charge of distribution's line*.

*Item that we don't supply.

HP61 doses the programmed quantity of feed to distribute with resolution to Kg and in the meantime it realizes the following functions:

- it verifies that during the distribution the feed reduces in the silo (stopping the distribution and signalling the alarm if a non-decrease of the weight occurs due to effect "bridge" of the feed in the silo);
- it verifies that the distribution of the programmed quantity of feed happens in a prefixed time (stopping the distribution and signalling the alarm if an overcoming of maximum time occurs);
- it verifies the signal of the sensor of maximum charge of distribution line of the feed (stopping the distribution when the sensor intervenes and starting it again with a certain time of delay when the sensor permits it);
- it records the Kg of feed that have been consumed from the first day of the cycle;
- it records the litres of water that have been consumed from the first day of the cycle;
- it verifies in each moment the feed that has been loaded.

The digital amplifier at 65.500 points with precision and a stability of 1 point on 65.500 and a termic drift of less than one point on 65.500 integrated on board of HP61 permits an exact control of the weighing, in order to connect every kind of load cells with an automatic procedure of cells calibration (no trimmers to adjust): pratically the precision of weighing system is the one that is declared of load cells.

      freccia su

 

HP62 Hopper weight controller

ico info   Limited quantities, ask This email address is being protected from spambots. You need JavaScript enabled to view it. for availability before placing an order !
pan HP62
 
 
 
 
 
Inputs:
 
Load cells
3 external contacts
 Outputs:
 
4 normally open contacts
 Range:
 
Multirange
 Including:
   ttl plug foto - Copia
Optionals:
 
ghp  ct  
     
   
  • Hopper weight controller with entry for load cells*
  • Digital amplifier at 65.500 points, integrated on board
  • Litres counter for water calculation*
  • aily start clock*
  • Sensor maximum charge of distribution's line*

*Item that we don't supply.

HP62 doses the programmed quantity of feed to distribute with resolution to Hectogram and in the meantime it realizes the following functions:

- it verifies that during the distribution the feed increases in the hopper (stopping the distribution and signalling the alarm if a non-decrease of the weight occurs due to effect "bridge" of the feed in the silo);
- it verifies that the distribution of the programmed quantity of feed happens in a prefixed time (stopping the distribution and signalling the alarm if an overcoming of maximum time occurs);
- it verifies that the quantity of feed that is present in the silo doesn't fall under the prefixed quantity of "minimum supply" (signalling with the alarm the overcoming of this condition);
- it verifies the signal of the sensor of maximum charge of distribution line of the feed (stopping the distribution when the sensor intervenes and starting it again with a certain time of delay when the sensor permits it);
- it records the Kg of feed that have been consumed from the first day of the cycle;
- it records the litres of water that have been consumed from the first day of the cycle;
- it verifies in each moment the feed that is present.

The digital amplifier at 65.500 points with precision and a stability of 1 point on 65.500 and a termic drift of less than one point on 65.500 integrated on board of HP62 permits an exact control of the weighing, in order to connect every kind of load cells with an automatic procedure of cells calibration (no trimmers to adjust): pratically the precision of weighing system is the one that is declared of load cells.


freccia su

 

HP63 Silos weight repeater

pan HP63W
 
Inputs:
  Bus 485
 Outputs:
  ---
 Range:
 
Kg / Qli
 Including:
   
Optionals:
   
     
HP63/W is a repeater of the silos weight so the value can be easily read near the silos.
It has been designed for outdoor installation and 1 units can be connected for each silos.
It can be connected to the 485 weight bus, available on the TLC2 loadcells amplifier located near the silos (only for connection with Gt Farm, Xfarm and Qfarm).
      freccia su

 

HP64 Hopper time/weight controller

pan HP64
 
 
 
 
 
Inputs:
 
4 external contacts
 Outputs:
 
3 normally open contacts
 Range:
 
---
 Including:
   ttl plug foto - Copia
Optionals:
 
ghp  ct   
     

Hopper time/weight controller without load cells, litres counter for water calculation*, daily start clock*, sensor maximum charge of distribution's line*.

*Item that we don't supply.

HP64 doses the programmed quantity (time/weight) of feed to distribute and in the meantime it realizes the following functions:

- it verifies that the distribution of the programmed quantity of feed happens in a prefixed time (stopping the distribution and signalling the alarm if an overcoming of maximum time occurs);
- it verifies the signal of the sensor of maximum charge of distribution line of the feed (stopping the distribution when the sensor intervenes and starting it again with a certain time of delay when the sensor permits it);
- it records the Kg of feed that have been consumed from the first day of the cycle;
- it records the litres of water that have been consumed from the first day of the cycle;

 

      freccia su

 

HP66 Ventilation & Cooling

pan HP66
 
Inputs:
 
1 temperature probe SX
1 humidity probe electronic 4-20mA / SXPS
 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
(10.0 ...99.9% Rh)
 Including:
 
ttl plug foto - Copia
Optionals:
 
ghp  ct hpal sxwt1 rhr ha20 
     freccia su

 

HP68 Lights sequence 

pan HP68
 
 
 
 
 
Inputs:
 
1 0-10v
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
---
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia
   
HP68 allows you to operate ceiling dual lamp with a lamp in regulation 0-10V (incandescent) and a lamp On-Off (neon).
In the initial phase (Dawn) it is adjusted increasing the brightness of incandescent lamps (via its 0-10V output of Gt Farm); reached the maximum% brightness of the lamps (incandescent) the neon lights are lit up, then the incandescent lamps are turned off (after a programmable delay time).
It continues with the neon lights on (and incandescent lamps off) until the initial phase of the sunset, when incandescent lights are 100% turned on, after this the neon lamps are turned off (after a delay time programmable).
The sunset is terminated with the arrival to the % of brightness programmed on Gt Farm.
In the case of a single ceiling lamp (with neon lamp in regulation 0-10V) you can control a line counter to switch off the lights.

freccia su

 

HP69 0-10V light control

pan HP69
 
 
 
 
 
Inputs:
 
1 external contact
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
---
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia
   
HP69 allows you to operate an output in 0-10V regulation with an ascending ramp and one descending: the start signal (start signal closed) powers up the ascending ramp that maintains the output value until the start of the descent ramp (start signaI open).
Furthermore below the set minimum % set of brightness the relay turns completely the lamps off.

freccia su

   

----------------------------------------------------------------

  

HP70 Ventilation proportional 0-10V

pan HP70
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
1 output 0-10V
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sxttl plug foto - Copia
Optionals:
 
ghp  ct   
     freccia su

 

HP71 0-5v Steps translator

pan HP71
 
Inputs:
 
1 0-5v
 Outputs:
 
4 normally open contacts
1 fuse protected (T 4A) exchange contact

 Range:
 
---
 Including:
   
Optionals:
 
ghp  ct   ttl plug foto - Copia
     freccia su

 

HP72 Sprinkler controller

pan HP72
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
2 fuse protected (T 4A) exchange contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia
     freccia su

 

HP73 Proportional feedback

pan HP73
 
Inputs:
 
1 0-10V
1 Feedback potentiometer
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
---
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia 
     freccia su

 

HP74 Ventilation controller 0-10V + 4 steps On-Off

pan HP74
 
Inputs:
 
1 temperature probe SX (with min & max value recording)
 Outputs:
 
1 output 0-10v
1 fuse protected (T 4A) exchange contact
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia  hdy6
     freccia su

 

HP75 CO2 Surveyor

pan HP75
 
 
 
 
 
Inputs:
 
carbon dioxide probe (CO2)
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(0...10.000ppm)
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia  co2e
       
HP75 keeps control on the CO2 ambient value and records the min/max daily value up to 99 days cycle (and hourly values of the last 60 hours).
Afterwards the oldest daily and hourly records are automatically deleted by the new ones.
A CO2 alarm value can be set so an output contact is activated.
      freccia su

 

HP76 Humidity Surveyor (electronic probe)

pan HP76
 
 
 
 
 
Inputs:
 
1 humidity probe electronic
 Outputs:
 
1 fuse protected (T 4A) exchange contact
 Range:
 
(0...100% Rh)
 Including:
   
Optionals:
 
ghp  ct  ttl plug foto - Copia  rhr
       
HP76 keeps control on the humidity ambient value and records the min/max daily value up to 99 days cycle (and hourly values of the last 60 hours).
Afterwards the oldest daily and hourly records are automatically deleted by the new ones.
A humidity alarm value can be set so an output contact is activated.
      freccia su

  

HP77 Humidity Surveyor (psychrometer probe)

pan HP76
 
 
 
 
 
Inputs:   1 temperature probe SX (dry)
1 temperature probe SX1 (wet)
 Outputs:   1 fuse protected (T 4A) exchange contact
 Range:   (0.0...100% Rh)
 Including:    
Optionals:   ghp  ct  ttl plug foto - Copia  wt1
       
HP77 keeps control on the humidity ambient value and records the min/max daily value up to 99 days cycle (and hourly values of the last 60 hours).
Afterwards the oldest daily and hourly records are automatically deleted by the new ones.
A humidity alarm value can be set so an output contact is activated.
      freccia su

 

HP79 Single-level hygrostat (electronic probe)

pan HP76
 
 
 
 
 
Inputs:   1 humidity probe electronic
 Outputs:   1 fuse protected (T 4A) exchange contact
 Range:   (0...100% Rh)
 Including:    
Optionals:   ghp  ct  ttl plug foto - Copia  rhr
      freccia su

 

 

 

  

HP96 Amperometric controller

pan HP96
 
Inputs:
 
 
3 TA
1 temperature probe SX

 Outputs:
 
4 normally open contacts
 Range:
 
(-50.0 °C < > +115.0 °C) (-58.0 °F < > +239.0 °F)
 Including:
 
sx
Optionals:
 
ghp  ct  ttl plug foto - Copia hta3