SC6F
SC6F realizes a complete ventilation, heating and flap of air entrance management and alarm in a thermoventilated zootechnic environment with continuous speed controller for single-phase fans . The flexibility of the program permits a total adaptation at the system to be verified in order to operate the different system's components in a perfect way.
Speed regulation of fan is of continuous type with 1% resolution; and more over it's possible to stop ventilation under a certain temperature level (safety stop); it's possible to set a cycled timer working in connection to minimum ventilation, which assures a minimum replacement air when there is not the heating-system or when there is a failure.
Speed regulation of fan is of continuous type with 1% resolution; and more over it's possible to stop ventilation under a certain temperature level (safety stop); it's possible to set a cycled timer working in connection to minimum ventilation, which assures a minimum replacement air when there is not the heating-system or when there is a failure.
SC6E
SC6E realizes a complete ventilation plan, heating and alarm management into thermoventilated zootechnic environment. The flexibility of the programm permits a total adaptation at the system to be verified in order to operate to different system's components in perfect way.
Speed regulation of fan is of continuous type with 1% resolution; and more over it's possible to stop ventilation under a certain temperature level (safety stop); it's possible to set a cycled timer working in connection to minimum ventilation, which assures a minimum replacement when there is not the heating-system or when there is a failure.
Speed regulation of fan is of continuous type with 1% resolution; and more over it's possible to stop ventilation under a certain temperature level (safety stop); it's possible to set a cycled timer working in connection to minimum ventilation, which assures a minimum replacement when there is not the heating-system or when there is a failure.
SC6D
SC6D realizes a complete ventilation plan, heating and alarm management into thermoventilated zootechnic environment.
Speed regulation of fan is of continuous type with 1% resolution; with SCSL power's unit it's possible to increase the regulator capacity for total load superior to 6 AMP (every SCSL has a capacity of 6A, it is possible to expand up to 10 SCSL).
Minimum and maximum environmental temperatures are memorized to permit a correct data stores program; the settings and the statement of the time are kept in memory also if there is a power failure for more than 10 years; no-one external interference can interrupt or change program's working.
Speed regulation of fan is of continuous type with 1% resolution; with SCSL power's unit it's possible to increase the regulator capacity for total load superior to 6 AMP (every SCSL has a capacity of 6A, it is possible to expand up to 10 SCSL).
Minimum and maximum environmental temperatures are memorized to permit a correct data stores program; the settings and the statement of the time are kept in memory also if there is a power failure for more than 10 years; no-one external interference can interrupt or change program's working.