Flag ITA dark   Flag ENG dark

HD line system potentiality

pan HP potenzialitàView the HD line full specifications

Weights, measures, specific inputs / outputs, etc.

 

 

INPUTS: - 4 ANALOG 3870 points NTC -50°C...+115°C (SX)
- 12 conversions/sec PT100/PT1000 (2 wire) Thermocouple J-K-N-R-S-T
- digital filtering 0-5V / 4-20mA
- thermal drift typ. 1 point. Potentiometer / Switch / Commutator
  WX (anemometer) / LX (luxmeter) / HLTA
 
LOAD CELL INPUT: - Input range: -20mV...+20mV (4mV/V)
- s/w limit cells E.S. range: 0.8mV...3.3mV/V
- Resolutions  (Field over the entire scale 2mV/V): 16384 points
- Converter temperature stability (-10°C...+55°C): 1 point
- Load cells power supply (max 4 cells 350Ohm): 5V -/+ 2%
- Fied reading in common way: 1.5V...3.5V
 
OUTPUT: - 6 relays 4 AMP-AC1 (Mechanical endurance 20 millions operations)
(Electrical endurance 0.3 millions operations)
D/A or DIG. INP (HISO)  
DIGITAL OUTPUT (HDY6)  
 
DIALOGUE: - Until 5 Display H=20mm
  - 12 Status lamps
  - 6 Key lamps
  - 8 Tactile keys (Endurance 3 millions operations)
 
COMMUNICATION: Asynchronous serial TTL full duplex 2400 BAUD / RS485 half duplex 9600 BAUD
- Printer (PR24)
- RS232C (HRSS)
- RS485 insulated (HBOX)
 
PERIPHERAL: Synchronous serial 4 wires (SPI) 1MHz
- 2 A/D load cells (HLCP)
- 24 Driver relays (HR24)
- 2 A/D 16 bit (2000/Sec) (HD16)
- 2 relays option (HPAL)
-8 channells 12 bit AD conv. (HAD8)
 
INTELLIGENCE: HC11 Freescale / 16F Microchip
ROM until 12 Kbytes Nonvolatile
RAM until  1/2 Kbytes Volatile
EEPROM until 1/2 Kbytes Pseudo nonvolatile
Clock 2 MHz (0.5 uSec CPU cycle)
Data integrity -40....+85 °C
 
USING: Panel mounting dim.: 144x96x77mm Weight: 990g
Power supply: 230Vac (+10%/-15%) 50-60Hz (other voltages on request: 115Vac, 24Vac, 24Vdc, 12Vdc)
Power consuption typical: 7VA
Operatibility: -10°C....+55°C
Keyboard waterproof: IP55
 
EMC: EN 50081-1 (1992)(Emission) EN 50082-2 (1995)(Immunity)

Fully compliance with European directive 89/336/EEC for electromagnetc compatibility in hard industry and residential environment.
Tests performed and documentated in an official accreditated competent body.
As just certified with the conformity declaration and verified by tens of thousands of settings, our regulation modules have exceeded the strict directives EN 50082-2 (immunity in heavy industrial environment) with no need to use other screened cable, optical fibres, anti-radiation envelope and other help acts to correct some possible integrity absences.
To consumer advantage, the HP modules satisfy the normal conditions of functioning as well as they have been produced.

 
LVD: EN / IEC 61010-1 (low voltage) :Safety electric standards concerning low-voltage-directive 73/23/EEC and successes are largerly reached